Sönmez Mühendislik logo
TREN
Turkcell Datacenter

Data Centres · 2025

Turkcell Datacenter

Developed for Turkcell, this data center is an engineering project requiring technical infrastructure that meets high security and performance standards.

Project Facts

Year
2025
Building type
Data Centres
Engineering
Sönmez Mühendislik

Project

About Turkcell Datacenter

Developed for Turkcell, this data center is an engineering project requiring technical infrastructure that meets high security and performance standards.

The data centre projects carried out for Turkcell cover the engineering requirements specific to data centres: uninterrupted power, precision cooling and high floor loads. The two projects, in 2025 and 2026, address the company's growing digital infrastructure needs.

Turkcell Datacenter is one of the reference projects in Sönmez Mühendislik's technology centers, cultural and social facilities portfolio. Since 1995, Sönmez Mühendislik has provided structural, electrical, mechanical and infrastructure engineering with BIM coordination for projects in Türkiye and abroad.

Approach

Engineering for data centres

With their requirements for uninterrupted power, precision cooling and redundant infrastructure, data centres are among the most critical engineering projects.

  • High-load floors and seismic design
  • MV/LV distribution, UPS and generator infrastructure
  • Precision cooling and hot/cold aisle layout
  • BIM coordination in services-dense areas

Engineering

Key engineering topics for this type of project

Continuity and efficiency are the core design criteria for data centres. Power density per rack, redundancy level and cooling strategy shape the entire structural, electrical and mechanical design.

  1. 01

    Structure for heavy loads

    The structure is sized separately for racks, UPS, batteries and raised floors.

  2. 02

    Redundant power

    MV/LV distribution, UPS and generators are configured to the target redundancy level (e.g. N+1, 2N).

  3. 03

    Precision cooling

    Hot/cold aisle separation and precision air conditioning deliver efficient cooling.

  4. 04

    Fire protection

    Gas suppression and very early smoke detection systems are used.

FAQ

Frequently asked questions

What does the Tier level mean in data centre projects?

The Uptime Institute Tier classification (Tier I–IV) defines the redundancy of a data centre and its ability to keep running during maintenance; higher tiers need more redundant power and cooling.

What is PUE in a data centre?

Power Usage Effectiveness is the ratio of total facility energy to IT equipment energy; the closer to 1, the more efficient the facility.

What matters in the structural design of a data centre?

Heavy equipment loads from racks, UPS and batteries, raised floors and restraining equipment during earthquakes.

Related

Related services

Planning a similar project?

Share the type and size of your project; we will plan the structural, electrical, mechanical and BIM scope together and send you our proposal.