Sönmez Mühendislik logo
TREN
Eyüp Kiptaş Housing Project — 135,000 m²

Blog · Structural · Seismic · 6 min read · Updated: · Sönmez Mühendislik Engineering Team

Earthquake-code compliant structural design: the foundation of a safe building

Short answer: Structural design is the calculation and detailing of the load-bearing system that safely carries a building's self-weight, live loads, wind and earthquakes. In Türkiye it is based on the geotechnical report and the Turkish Building Earthquake Code (TBDY 2018); good design is both safe and economical.

Türkiye is an earthquake country, and a building's safety depends first of all on its structural design. As one of Türkiye's long-established engineering offices, we have carried this responsibility for 32 years.

It all starts with the ground

Soil class, bearing capacity, groundwater and liquefaction risk directly determine the foundation type and seismic design parameters.

Turkish Building Earthquake Code (TBDY 2018)

In force since 2019, the code defines seismic hazard for each specific site and sets design rules according to occupancy, height and structural system. Buildings that must remain operational after an earthquake, such as hospitals, schools and data centers, have higher performance targets.

GroundGeotechnical reportSystemStructural choiceAnalysisSeismic calculationDetailingRebar, connectionsCoordinationMEP openings
Figure 1 — Steps of structural design.

Choosing the right structural system

SystemTypical buildingsNote
RC frame + shear wallsHousing, offices, hospitalsThe most common solution in Türkiye
SteelLong-span and industrial buildingsLight, fast erection
Composite / hybridTall and special buildingsNeeds intensive multi-discipline coordination

A heavier structure than necessary increases both cost and seismic load.

Coordination with building services

Duct openings in beams, shafts in slabs and heavy equipment loads directly affect the structural design. Developing structural, electrical and mechanical design together in one office and one BIM model prevents uncontrolled drilling and cutting later.

See our Services page for details of Sönmez Mühendislik's services, and our Blog for more technical articles.

Frequently asked questions

Click a question to see the answer.

Eyüp Kiptaş Housing Project — 135,000 m²
BasicsWhat is the difference between architectural and structural design?
Architectural design defines the layout of spaces; structural design calculates and details the system that safely carries loads and earthquakes.
GroundCan structural design be done without a geotechnical report?
No. The geotechnical report is a required input for seismic parameters and foundation design.
ExistingHow can I find out whether my building is earthquake resistant?
Through a seismic performance assessment based on the existing drawings and on-site investigations.
Eyüp Kiptaş Housing Project — 135,000 m²
CostIs a safer building more expensive?
Not always. The right structural system and optimisation can improve safety while reducing material quantities.

Talk to us about a safe and economical structural system.

Since 1995, Sönmez Mühendislik has delivered structural, electrical, mechanical and BIM projects in Türkiye and abroad, and is one of Türkiye's long-established engineering offices. With more than 80 specialists we provide engineering design, technical consultancy and project management.