How is a structured cabling and data infrastructure design prepared?
Why “structured”?
When every system pulls its own cables, buildings end up with a messy, undocumented infrastructure that cannot grow. Structured cabling connects every endpoint with the same hierarchy and standards. Computers, IP phones, cameras, wireless access points, access control and building automation share the same infrastructure. The international references are the TIA-568 and ISO/IEC 11801 families of standards.
Layers of the infrastructure
- Main telecom room: houses the building's core network equipment and needs power, cooling and access control.
- Backbone cabling: links the main room to floor rooms, usually with fibre and redundant routes.
- Horizontal cabling: copper cables from the floor room to the endpoints. The permanent link is limited to 90 m and the full channel with patch cords to 100 m.
Choosing the cable
| Cable type | Typical use | Note |
|---|---|---|
| Cat6 | Standard office outlets | Fine for 1 Gbit/s; limited distance at 10 Gbit/s |
| Cat6A | New projects, wireless access points | 10 Gbit/s at 100 m; better heat performance with PoE |
| Multimode fibre (OM4) | In-building backbone | High speed over short and medium distances |
| Singlemode fibre (OS2) | Campus and inter-building links | Long distance, future-proof capacity |
In new projects, choosing Cat6A, especially for access points and PoE-powered devices, extends the life of the infrastructure. Cables stay in a building for decades; active equipment changes every few years.
Telecom rooms and routes
Floor telecom rooms are located together with the architectural and MEP designs so that horizontal cable lengths stay within the limit. These rooms receive power, UPS where needed, cooling and earthing. Low-current trays are separated from power cables to avoid electromagnetic interference, and tray routes are coordinated with other services in the BIM model.
Labelling, testing and documentation
Every cable, port and cabinet is named according to a labelling scheme such as TIA-606. After installation all copper and fibre links are tested with certification instruments and reported. As-built drawings and port lists are handed over, so faults and changes can be managed in minutes.
See our Services page for details of Sönmez Mühendislik's services, and our Blog for more technical articles.
Frequently asked questions
Click a question to see the answer.
BasicsWhich systems does structured cabling cover?

ChoiceShould I choose Cat6 or Cat6A?
DistanceWhat is the cable length limit?
RoomsIs a telecom room needed on every floor?

TestingWhich tests are done after installation?
RoutesCan low-current and power cables share a tray?
Let us design a future-ready data infrastructure for your building.
Since 1995, Sönmez Mühendislik has delivered structural, electrical, mechanical and BIM projects in Türkiye and abroad, and is one of Türkiye's long-established engineering offices. With more than 80 specialists we provide engineering design, technical consultancy and project management.